Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU

    Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
     
    Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers
    • Buy cheap RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU from wholesalers

    RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU

    RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU


    1. Introduction

    MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction, and is composed of sensors and converters. Used to measure the conductivity of liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water and raw water conductivity is about 100 ~ 500μs/cm), and it can also be used to measure acid, alkali, brine, pulp or pulp and other media. However, these media cannot contain a large amount of magnetic substances and bubbles.


    3. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    4.Selection of Electrode Materials


    316LGood resistance to the corrosion of nitric acid, <5% sulfuric acid under room temperature, acetic acid, alkaline fluid, sulfite under certain pressure, seawater and scetic acid, etc. It can be widely used in petrochemical urea, vinylon.
    HbGood resistance to the all the concentration of hydrochloric acid below the boiling point, also resistance tothe corrosion of non-oxidizing acid, alkali, salt like sulfuric acid phosphoric acid hydrofluoric acid, organic acids.
    HcResistance to the corrosion of oxidizing acids like metric acid, mixed acid. The mixture of chromium acid and sulfuric acid, and salts of oxidative, like Fe3+, Q3+, and some other oxidants, like hypochlorite salt solution higher than normal tmperature and seawater.
    TiResistance the corrosion of seawater, various chlorides, hypochlorite, oxidizing acid(including fuming nitric acid), and organic acid or alkali, but don't be resistance to the corrosion of pure reducint acid(like sulfuric acid, hydrochloric acid). But if acid includes oxidants(like nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    5. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

    2. Low abrasion resistance.

    3. Low negative pressure resistance

    1. -25~140ºC

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80ºC

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65ºC

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1. Good resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

    2. Avoid strong oxidants

    1. <80ºC

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180ºC

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180ºC

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    6. Configuration

    MLF Series Electromagnetic Flow Meter Configuration
    ModelMLF
    Sensor InstallationSFlange Type Sensor
    CInsertion Type Sensor
    OOthers
    Pipeline Diameter1010mm
    1515mm
    2020mm
    ......
    20002000mm
    Electrode InstallationFStandard Fixed Type
    Electrode MaterialA316L SS
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    GOthers
    Liner MaterialRRubber
    PPTFE
    OOthers
    Pipe MaterialB304 SS (Standard)
    C316 SS
    Flange TypeGGB (Standard)
    AANSI
    JJIS
    BBS
    OOthers
    Flange MaterialA304 SS
    B316 SS
    C#20 Carbon Steel (Standard)
    Cover MaterialD304 SS
    E316 SS
    FCarbon Steel+ Epoxy Metallic Paint (Standard)
    Matching Flange0Without Matching Flange (Standard)
    1With Matching Flange
    Ground Ring0Without Ground Ring (Standard)
    1With Ground Ring
    Rated Pressure101.0MPa
    161.6MPa
    252.5MPa
    404.0MPa
    Working TemperatureE≤60℃
    H≤180℃(Divided Type)
    TypeIIntegrated Type
    DDivided Type
    OutputPPulse
    A4-20mA
    GRS485
    HHart
    QOthers
    Power Supply0220VAC
    124VDC
    2Battery-powered
    Protection Class0IP65 (Integrated/Divided Type)
    1IP67 (Divided Type)
    2IP68 (Divided Type)
    Other FeaturesRHeat Energy Function
    PWith PT1000
    BWithout PT1000
    Explosion Proof0None
    EXExplosive Proof

    7.Company Profile


    Melan Measurement & Control Instruments is located in Shanghai City. It is a high-tech manufacturer specialized in the design, development, manufacturing and sale of measurement and control instruments.


    Our products are widely used in various fields, including electricity, chemical industry, metallurgy, brewing, oil and gas, textile, water conservancy, environmential protection, etc.

    We own independent-courtyard modemized manufacturing workshops and an open office building. Melan has accumlated production and management experience in instruments from European and American and domestic famous companies.

    We own first-class talent team, and all the products have reached advanced level at home and abroad. We provide our customers with complete and professional test control solutions and high-tech and high-quality products.

    Melan is your reliable friend and partner. We are willing to try our best as dedication and perfection as motivation.


    8.FAQ

    Q: How long will you give me the reply?
    A: We will contact you in 5 hours as soon as we can.

    Q: What is the warranty of your prducts?
    A: Our warranty is 12 months after the shipping date.

    Q: What is the lead time of your products?
    A: Normally our factory lead time is 10-12 working days.

    Q: Can I OEM your products?
    A: OEM and ODM customization are welcomed.

    Q: What is your MOQ?
    A: We have no MOQ limit, small quantity order is acceptable.

    Q:What is the transport?
    A: Express such as DHL, FedEx, UPS for freight prepaid, and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by sea.

    Quality RS485 Output Magnetic Flow Meter Fatty Acid Heat BTU for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)