Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output

    Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
     
    Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
    • Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
    • Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
    • Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
    • Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
    • Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers
    • Buy cheap Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output from wholesalers

    Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output

    Stainless Steel Separate Type Electromagnetic Flow Meter with RS485 Output


    1. Introduction

    The MLF electromagnetic flow meter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μs/cm (tap water, raw water conductivity of about 100 to 500μs/cm), can also be used to measure acids, alkali, brine, pulp or pulp and other media. However, these media must not contain large amounts of magnetic substances and bubbles.

    MLF electromagnetic flow meter is an instrument for measuring liquid flow. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textiles, food, urban management, water plants and other industries flow metering.

    .


    2. Features
    The MLF electromagnetic flow meter is for explosive proof design.
    It has the function of low conductivity measurement.
    It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages languages for option to satisfy different customers’ requirements.
    It has the function of self-adjustment and self-checking.
    A variety of outputs are optional:Hart, RS485, Profibus, 4-20mA, Frequency, Pulse.


    3. Application:

    MLF electromagnetic flow meter is a kind of instrument,used for measuring the flow conductivity liquid, which is widely used in flow measuring of Metallurgy, Chemical industry, Paper industry, Environmental protection, Oil industry, Textile industry, Food industry and City administration,Water works,etc.


    4. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    5. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1 The most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong bases and various organic solvents, but not resistant to the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

    2 Low wear resistance.

    3 Low negative pressure resistance.

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

    2 Avoid strong oxidants

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    6. Dimensional Sketches

    a. Dimension of Converter

    Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output

    Divided Type


    Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output


    Integrated Type


    Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    7. Configuration

    MLF Series Electromagnetic Flow Meter Configuration
    ModelMLF
    Sensor InstallationSFlange Type Sensor
    CInsertion Type Sensor
    OOthers
    Pipeline Diameter1010mm
    1515mm
    2020mm
    ......
    20002000mm
    Electrode InstallationFStandard Fixed Type
    Electrode MaterialA316L SS
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    GOthers
    Liner MaterialRRubber
    PPTFE
    OOthers
    Pipe MaterialB304 SS (Standard)
    C316 SS
    Flange TypeGGB (Standard)
    AANSI
    JJIS
    BBS
    OOthers
    Flange MaterialA304 SS
    B316 SS
    C#20 Carbon Steel (Standard)
    Cover MaterialD304 SS
    E316 SS
    FCarbon Steel+ Epoxy Metallic Paint (Standard)
    Matching Flange0Without Matching Flange (Standard)
    1With Matching Flange
    Ground Ring0Without Ground Ring (Standard)
    1With Ground Ring
    Rated Pressure101.0MPa
    161.6MPa
    252.5MPa
    404.0MPa
    Working TemperatureE≤60℃
    H≤180℃(Divided Type)
    TypeIIntegrated Type
    DDivided Type
    OutputPPulse
    A4-20mA
    GRS485
    HHart
    QOthers
    Power Supply0220VAC
    124VDC
    2Battery-powered
    Protection Class0IP65 (Integrated/Divided Type)
    1IP67 (Divided Type)
    2IP68 (Divided Type)
    Other FeaturesRHeat Energy Function
    PWith PT1000
    BWithout PT1000
    Explosion Proof0None
    EXExplosive Proof

    7. Instrument Detection & Maintenance


    Electromagnetic flow meters have a self-diagnosis function. In addition to power and hardware circuit failures, the system also alerts to other faults in general use. This information is prompted in the lower right corner of the screen.


    1 Maintenance and repair

    a) The sensor installation site should comply with section IV requirements, please keep the housing clean;

    b) The transmitter should be placed in a clean, ventilated and dry place;

    c) The instrument needs to be checked every two years and for high-precision users, the instrument needs to be submitted for review.


    2 Transport and storage

    a) The instrument must be packed before transport and handled with care.

    b) Storage sites must be dry and ventilated to avoid the erosion of corrosive gases, and the ambient temperature should not be too low or too high

    c) Storage time should preferably not exceed three years.


    3 Out-of-the-box inspection

    a) The package cannot be opened with a heavy hammer and care should be taken not to damage the instrument

    b) Check the contents carefully according to the packing slip.


    Quality Separate Type Electromagnetic Flow Meter Stainless Steel With RS485 Output for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)