Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated

    Buy cheap High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated from wholesalers
     
    Buy cheap High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated from wholesalers
    • Buy cheap High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated from wholesalers
    • Buy cheap High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated from wholesalers
    • Buy cheap High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated from wholesalers
    • Buy cheap High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated from wholesalers

    High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated

    Multi Language Integrated Electromagnetic Flow Meter for Sewage or Dirty Water


    1. Introduction

    MLF electromagnetic Flowmeter works according to Faraday's law of electromagnetic induction and is composed of sensors and converters. Used to measure the electrical conductivity of liquids or solids. In general, its electrical conductivity should be greater than 5 μ S / cm (the electrical conductivity of tap water and raw water is about 100 ~ 500 μS / cm), can also be used to measure various media such as acid, alkali, salt water, pulp or pulp. But these media cannot contain large amounts of magnetic materials and bubbles.

    MLF electromagnetic Flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, waterworks and other industries.


    2. Quick Details

    MLF electromagnetic Flowmeter is explosion-proof design.

    function of low conductivity measurement.

    There are 9 language options to meet the needs of different customers.

    Have self-regulation function and self-examination.

    different outputs are optional: hart, RS485 Profibus ,4-20 mA, frequency, pulse.


    3. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

    2 Low wear resistance.

    3 Low negative pressure resistance.

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1 Room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

    2 Avoid strong oxidizing agents

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    4. Selection of Electrode Materials

    Electrode MaterialMain Performance
    316L

    Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.

    Hb

    Good resistance to all concentrations of hydrochloric acid below boiling point, as well as non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

    Hc

    Corrosion resistance of oxidizing acids, such as nitric acid and mixed acid. A mixture of chromic acid and sulfuric acid, oxides, such as Fe3+,Q3+, and other oxidants, such as a mixture of hypochlorite solution above normal temperature and seawater.

    Ti

    Resistant to corrosion of seawater, various chlorides, hyalphates, oxidizing acids (including smoke nitric acid), organic acids or alkalis, but not pure reduced acids (e.g. sulphuric acid, hydrochloric acid). However, if the acid contains oxidants (e.g. nitric acid, Fe3, Q3), corrosion resistance is reduced.

    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    5. Dimensional Sketches

    a. Dimension of Converter

    High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated

    Divided Type


    High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated


    Integrated Type


    High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    6. Configuration

    MLF Series Electromagnetic Flow Meter Configuration
    ModelMLF
    Sensor InstallationSFlange Type Sensor
    CInsertion Type Sensor
    OOthers
    Pipeline Diameter1010mm
    1515mm
    2020mm
    ......
    20002000mm
    Electrode InstallationFStandard Fixed Type
    Electrode MaterialA316L SS
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    GOthers
    Liner MaterialRRubber
    PPTFE
    OOthers
    Pipe MaterialB304 SS (Standard)
    C316 SS
    Flange TypeGGB (Standard)
    AANSI
    JJIS
    BBS
    OOthers
    Flange MaterialA304 SS
    B316 SS
    C#20 Carbon Steel (Standard)
    Cover MaterialD304 SS
    E316 SS
    FCarbon Steel+ Epoxy Metallic Paint (Standard)
    Matching Flange0Without Matching Flange (Standard)
    1With Matching Flange
    Ground Ring0Without Ground Ring (Standard)
    1With Ground Ring
    Rated Pressure101.0MPa
    161.6MPa
    252.5MPa
    404.0MPa
    Working TemperatureE≤60℃
    H≤180℃(Divided Type)
    TypeIIntegrated Type
    DDivided Type
    OutputPPulse
    A4-20mA
    GRS485
    HHart
    QOthers
    Power Supply0220VAC
    124VDC
    2Battery-powered
    Protection Class0IP65 (Integrated/Divided Type)
    1IP67 (Divided Type)
    2IP68 (Divided Type)
    Other FeaturesRHeat Energy Function
    PWith PT1000
    BWithout PT1000
    Explosion Proof0None
    EXExplosive Proof

    7. Instrument Detection & Maintenance

    The electromagnetic Flowmeter has the function of self-diagnosis. In addition to power supply and hardware circuit failures, the system also gives an alarm to other faults in general use.These messages are prompted in the lower right corner of the screen.


    1 Maintenance and repair.

    A) the sensor installation site should meet the requirements of Section 4, please keep the shell clean and tidy.

    B) the transmitter should be placed in a clean, ventilated and dry place.

    C) it needs to be checked every two years, and for high-precision users, the instrument needs to be submitted for review.


    2 Transportation and storage.

    A) the equipment must be packed before transportation and handled carefully during loading and unloading.

    B) the storage place must be dry and ventilated to avoid the erosion of corrosive gases and the ambient temperature should not be too low or too high.

    C) the storage time should not exceed three years.


    3. Out-of-the-box inspection.

    A) the package cannot be opened with a heavy hammer, be careful not to damage the instrument.

    B) carefully check the contents according to the packing list.

    Quality High Resistance Sewage Electromagnetic Flow Meter Multi Language Integrated for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)