Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement

    Buy cheap Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement from wholesalers
     
    Buy cheap Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement from wholesalers
    • Buy cheap Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement from wholesalers
    • Buy cheap Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement from wholesalers

    Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement

    Multi-language Electro Magnetic Flow Meter with English / Korean / Polish / Turkish / French / Portuguese


    1. Introduction

    The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a transducer. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μS/cm (tap water, raw water conductivity of about 100 ~ 500μS/cm), can also be used to measure acid, alkali, salt water, pulp or pulp and other media. However, these media should not contain large amounts of magnetic material and air bubbles.

    MLF electromagnetic flowmeter is a kind of instrument to measure liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries flow measurement.


    2. Quick Details

    MLF electromagnetic flowmeter is explosion-proof design.

    Function of low conductivity measurement.

    There are 9 languages options to meet the needs of different customers.

    Self-regulating function and self-checking.

    Different outputs are optional: Hart, RS485,Profibus, 4-20mA, frequency and pulse.


    3. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1. Have the most stable chemical properties in plastic and resistance to boiling hydrochlor and sulfuric acid, nitric acid aqua regia, strong alkali, and all kinds of organic solvents, but can not resist the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

    2. Low abrasion resistance.

    3. Low negative pressure resistance

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1. Good resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

    2. Avoid strong oxidants

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    4. Selection of Electrode Materials

    Electrode MaterialMain Performance
    316LGood resistance to the corrosion of nitric acid, <5% sulfuric acid under room temperature, acetic acid, alkaline fluid, sulfite under certain pressure, seawater and scetic acid, etc. It can be widely used in petrochemical urea, vinylon.
    Hb

    Good resistance to the all the concentration of hydrochloric acid below the boiling point, also resistance tothe corrosion of non-oxidizing acid, alkali, salt like sulfuric acid phosphoric acid hydrofluoric acid, organic acids.

    HcResistance to the corrosion of oxidizing acids like metric acid, mixed acid. The mixture of chromium acid and sulfuric acid, and salts of oxidative, like Fe3+, Q3+, and some other oxidants, like hypochlorite salt solution higher than normal tmperature and seawater.
    Ti

    Resistant to corrosion of seawater, various chlorides, hyalphates, oxidizing acids (including smoke nitric acid), organic acids or alkalis, but not pure reduced acids (e.g. sulphuric acid, hydrochloric acid). However, if the acid contains oxidants (e.g. nitric acid, Fe3, Q3), corrosion resistance is reduced.

    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    5. Dimensional Sketches

    a. Dimension of Converter

    Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement

    Divided Type


    Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement


    Integrated Type


    Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    6. Instrument Detection & Maintenance

    The electromagnetic flowmeter has a self-diagnostic function. In addition to power supply and hardware circuit failures, the system also alarms other failures in general use. These messages will give corresponding prompts in the lower right corner of the screen.


    1 Maintenance and repair

    a) The sensor installation site should meet the requirements of Section 4, please keep the housing tidy;

    b) The transmitter should be placed in a clean, ventilated and dry place;

    c) It needs to be inspected every two years. For high-precision users, the instrument needs to be submitted for review.


    2 Transportation and storage

    a) The instrument must be packaged before transportation, and be handled with care when loading and unloading.

    b) The storage place must be dry and ventilated to avoid corrosive gases, and the ambient temperature should not be too low or too high;

    c) The storage time should not exceed three years.


    3. Unpacking inspection

    a) The package cannot be opened with a heavy hammer, be careful not to damage the instrument

    b) Check the contents carefully according to the packing list.


    7. Product Photos

    Quality Multi - Language Electronic Magnetic Flow Meter Low Conductivity Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)