Sign In | Join Free | My burrillandco.com
Home > Industrial Flow Meter >

Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy

    Buy cheap Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy from wholesalers
     
    Buy cheap Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy from wholesalers
    • Buy cheap Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy from wholesalers
    • Buy cheap Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy from wholesalers
    • Buy cheap Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy from wholesalers
    • Buy cheap Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy from wholesalers

    Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy

    6 Inch Electromagnetic Flow Meter Coal Slurry Made in China Price List


    1. Introduction

    MLF electromagnetic flow meter, composed of sensor and converter, works based on Faraday’s law of electromagnetic induction law. It is used to measure electrical conductivity of liquid or solid. Generally, the electrical conductivity should be over 5υS/cm(electrical conductivity of tap water, raw water is about 100~500υS/cm),It can also be used to measure various media like acid, alkali, saline solution, paper pulp or pulp and so on. But these media can’t contain a lot of magnetic materials and bubbles.

    MLF electromagnetic flow meter is a kind of instrument which is used for measuring the flow conductivity liquid. The meter is widely used in flow measuring of Metallurgy, Chemical Industry, Paper Industry,Environmental Protection, Oil Industry, Textile Industry, Food Industry and City Administration, Water Works,etc.


    2. Quick Details
    The MLF electromagnetic flow meter is for explosive proof design.
    It has the function of low conductivity measurement.
    It has 9 languages for option to satisfy different customers’ requirements.
    It has the function of self-adjustment and self-checking.
    A variety of outputs are optional:Hart, RS485, Profibus, 4-20mA, Frequency, Pulse.


    3. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    4. Selection of Electrode Materials

    Electrode MaterialMain Performance
    316L

    Good corrosion resistance to nitric acid, corrosion of < 5% sulfuric acid, acetic acid, alkaline liquid, sulfite, sea water, acetic acid under certain pressure at room temperature, can be widely used in petrochemical urea, vinylon and so on.

    Hb

    Good resistance to all concentrations below boiling point of hydrochloric acid, but also resistant to non-oxidizing acids, alkalis, sulphuric acid, phosphoric acid, hydrofluoric acid, organic acid corrosion.

    Hc

    Corrosion resistance of oxidizing acids, such as nitric acid and mixed acid. A mixture of chromic acid and sulfuric acid, oxides, such as Fe3+,Q3+, and other oxidants, such as a mixture of hypochlorite solution above normal temperature and seawater.

    Ti

    It is resistant to corrosion of sea water, various chlorides, hypochlorite, oxidizing acid (including fuming nitric acid), organic acid or alkali, but not pure reducing acid (such as sulfuric acid, hydrochloric acid).

    However, if the acid contains oxidants (such as nitric acid, Fe3+, Q3 +), the corrosion resistance will be reduced.

    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    5. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1 The most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong bases and various organic solvents, but not resistant to the corrosion of chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, liquid oxygen and ozone.

    2 Low wear resistance.

    3 Low negative pressure resistance.

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1 Resistance to room temperature, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide and potassium hydroxide

    2 Avoid strong oxidants

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    6. Dimensional Sketches

    a. Dimension of Converter

    Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy

    Divided Type


    Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy


    Integrated Type


    Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    7. Configuration

    MLF Series Electromagnetic Flow Meter Configuration
    ModelMLF
    Sensor InstallationSFlange Type Sensor
    CInsertion Type Sensor
    OOthers
    Pipeline Diameter1010mm
    1515mm
    2020mm
    ......
    20002000mm
    Electrode InstallationFStandard Fixed Type
    Electrode MaterialA316L SS
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    GOthers
    Liner MaterialRRubber
    PPTFE
    OOthers
    Pipe MaterialB304 SS (Standard)
    C316 SS
    Flange TypeGGB (Standard)
    AANSI
    JJIS
    BBS
    OOthers
    Flange MaterialA304 SS
    B316 SS
    C#20 Carbon Steel (Standard)
    Cover MaterialD304 SS
    E316 SS
    FCarbon Steel+ Epoxy Metallic Paint (Standard)
    Matching Flange0Without Matching Flange (Standard)
    1With Matching Flange
    Ground Ring0Without Ground Ring (Standard)
    1With Ground Ring
    Rated Pressure101.0MPa
    161.6MPa
    252.5MPa
    404.0MPa
    Working TemperatureE≤60℃
    H≤180℃(Divided Type)
    TypeIIntegrated Type
    DDivided Type
    OutputPPulse
    A4-20mA
    GRS485
    HHart
    QOthers
    Power Supply0220VAC
    124VDC
    2Battery-powered
    Protection Class0IP65 (Integrated/Divided Type)
    1IP67 (Divided Type)
    2IP68 (Divided Type)
    Other FeaturesRHeat Energy Function
    PWith PT1000
    BWithout PT1000
    Explosion Proof0None
    EXExplosive Proof

    8. Packing

    Quality Coal Slurry Electromagnetic Water Flow Meter 6 Inch Up To 0.2% Accuracy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)