    DN80 Integrated Industrial Flow Meter / EMF Electromagnetic Flow Meter

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    DN80 Integrated Industrial Flow Meter / EMF Electromagnetic Flow Meter

    DN80 Integrated EMF Electromagnetic Flow Meter with Cheap Price China


    1. Introduction

    1. The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a transducer. Used to measure the conductivity of a liquid or solid. In general, its conductivity should be greater than 5μS/cm (tap water, raw water conductivity of about 100 ~ 500μS/cm), can also be used to measure acid, alkali, salt water, pulp or pulp and other media. However, these media should not contain large amounts of magnetic material and air bubbles.

    MLF electromagnetic flowmeter is a kind of instrument to measure liquid fluidity. Widely used in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries flow measurement.


    2. Quick Details

    1). It is high resistance, fast response design can make undistorted collection of weak signal and fast response to the flow changes. Its range rate can reach 100:1.

    2). It has the function of low conductivity measurement.

    3). It has the consistency of converter’s interchange, which can avoid input parameters repeatedly.

    4). Wide range of power supply mode is available (DC: 18V-36V/AC: 85V-265V).

    5). It is the first domestic company that adopts the function of saving settings before delivery,which can avoid the loss of the parameters.

    6). It adopts the international leading excitation technology, which circuit is simple, stable,and reliable.

    7). It has the function of infrared remote control and button operation so as to make the operation more convenient.

    8). It provides the function of zero correction of sensor and automatic zero adjustment.

    9). It has Chinese, English, Korean, Polish, Turkish, French and Portuguese languages for option to satisfy different customers’ requirements.


    3. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    4. Selection of Electrode Materials

    Electrode MaterialMain Performance
    316L

    Good corrosion resistance of nitric acid, at room temperature <5% sulfuric acid, acetic acid, alkaline liquid, a certain pressure of sulphate, seawater, acetic acid and other corrosion, can be widely used in petrochemical urea, veline and so on.

    Hb

    Good resistance to all concentrations of hydrochloric acid below boiling point, as well as non-oxidizing acid, alkali, sulfuric acid, phosphoric acid, hydrofluoric acid and organic acid.

    Hc

    Corrosion resistance of oxidizing acids, such as nitric acid and mixed acid. A mixture of chromic acid and sulfuric acid, oxides, such as Fe3+,Q3+, and other oxidants, such as a mixture of hypochlorite solution above normal temperature and seawater.

    Ti

    Resistant to corrosion of seawater, various chlorides, hypochlorite, oxidizing acids (including fuming nitric acid), organic acids or bases, but not pure reductive acids (e.g., sulfuric acid, hydrochloric acid) etc. but if the acid contains oxidants (such as nitric acid, Fe3,Q3), the corrosion resistance will decrease.

    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    5. Dimensional Sketches

    a. Dimension of Converter

    DN80 Integrated Industrial Flow Meter / EMF Electromagnetic Flow Meter

    Divided Type


    DN80 Integrated Industrial Flow Meter / EMF Electromagnetic Flow Meter


    Integrated Type


    DN80 Integrated Industrial Flow Meter / EMF Electromagnetic Flow Meter

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    6. Configuration

    MLF Series Electromagnetic Flow Meter Configuration
    ModelMLF
    Sensor InstallationSFlange Type Sensor
    CInsertion Type Sensor
    OOthers
    Pipeline Diameter1010mm
    1515mm
    2020mm
    ......
    20002000mm
    Electrode InstallationFStandard Fixed Type
    Electrode MaterialA316L SS
    BHb
    CTa
    DTi
    EHc
    FTungsten Carbide
    GOthers
    Liner MaterialRRubber
    PPTFE
    OOthers
    Pipe MaterialB304 SS (Standard)
    C316 SS
    Flange TypeGGB (Standard)
    AANSI
    JJIS
    BBS
    OOthers
    Flange MaterialA304 SS
    B316 SS
    C#20 Carbon Steel (Standard)
    Cover MaterialD304 SS
    E316 SS
    FCarbon Steel+ Epoxy Metallic Paint (Standard)
    Matching Flange0Without Matching Flange (Standard)
    1With Matching Flange
    Ground Ring0Without Ground Ring (Standard)
    1With Ground Ring
    Rated Pressure101.0MPa
    161.6MPa
    252.5MPa
    404.0MPa
    Working TemperatureE≤60℃
    H≤180℃(Divided Type)
    TypeIIntegrated Type
    DDivided Type
    OutputPPulse
    A4-20mA
    GRS485
    HHart
    QOthers
    Power Supply0220VAC
    124VDC
    2Battery-powered
    Protection Class0IP65 (Integrated/Divided Type)
    1IP67 (Divided Type)
    2IP68 (Divided Type)
    Other FeaturesRHeat Energy Function
    PWith PT1000
    BWithout PT1000
    Explosion Proof0None
    EXExplosive Proof