Sign In | Join Free | My burrillandco.com
Home > Electromagnetic Flow Meter >

ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter

    Buy cheap ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter from wholesalers
     
    Buy cheap ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter from wholesalers
    • Buy cheap ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter from wholesalers
    • Buy cheap ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter from wholesalers

    ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter

    Ask Lasest Price
    Brand Name :
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter

    Digital Electromagnetic Flowmeter Water Flow Meter Price


    1. Introduction

    The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a converter. Used to measure the conductivity of liquids or solids. Under normal circumstances, its conductivity should be greater than 5μS/cm (the conductivity of tap water and raw water is about 100-500μS/cm), and it can also be used to measure acids, alkali, brine, pulp or pulp and other media. But these media cannot contain a lot of magnetic substances and bubbles.

    MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.


    2.Working Principle

    The principle of the sensor is based on Faraday’s law of electromagnetic induction.

    It is installed a pair of detection electrodes on the pipe wall,where the measurement pipe axis

    and magnetic field lines are vertical. When the conductive liquid cuts magnetic field lines and

    produces induced electromagnetic force.Which can be measured by the two electrodes on the

    meter pipe.The result can be calculated by formula: Induced electromotive force,(flow signal)

    E=KBDV

    E——Induced electromotive force,V;

    K——meter constant;

    B——Magnetic flux density,T;

    D——Internal diameter of measuring pipe,m;

    V——Average velocity of pipe section,m/s.

    1MLF Series Electromagnetic Flow Meter

    Assume the volume of liquid as qv(m3/s),qv=πD2V/4),so in the formula E=(4kB/πD)qv=kqv,

    K is meter constant,K=4kB/πD.

    Actually, the electromagnetic flow meter consists of two parts, transmitter and sensor, the

    measuring electrodes inspect the electromotive force, and transmit to the converter, the

    converter provides excitation current.

    E is usually called a flow signal, after processing the flow signal by converter, output 4~20 mA/

    pulse(or frequency) signal which is proportional to the flow rate, then the flow rate recording,

    adjusting can be achieved.


    3. Quick Details

    MLF electromagnetic flowmeter is explosion-proof design.

    Function of low conductivity measurement.

    There are nine language options to meet the needs of different customers.

    It has the function of self-regulation and self-examination.

    Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.


    4. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    5. Dimensional Sketches

    a. Dimension of Converter

    ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter

    Divided Type


    ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter


    Integrated Type


    ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    Quality ANSI RS485 IP68 DN15 Electromagnetic Flow Transmitter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)