Sign In | Join Free | My burrillandco.com
Home > Differential Pressure Transmitter >

Capacitive Gas Absolute DP Transmitter With Single Flange

    Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
     
    Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers
    • Buy cheap Capacitive Gas Absolute DP Transmitter With Single Flange from wholesalers

    Capacitive Gas Absolute DP Transmitter With Single Flange

    Ask Lasest Price
    Brand Name :
    Model Number : ML3000S
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 10000pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Capacitive Gas Absolute DP Transmitter With Single Flange

    Gas Absolute DP Transmitter Single Flange Differential Pressure Transmitter
    1. Introduction

    Differential pressure liquid level transmitter has single flange and double flange.

    1. The single flange is used to measure the liquid level of the open tank.
      Differential pressure range calculation method: need to measure the liquid level height (unit: m) × gravity acceleration (9.8) × measured medium density (unit: g / cm3, when the density of water is calculated as 1, the unit is g / cm3) Range (unit: KPa).
      The type selection must know the measuring medium, measuring range, medium temperature, process connection flange size and pressure rating and flange standard.
    2. Double flange is used to measure the liquid level of the closed tank.
      Differential pressure range calculation method: need to measure liquid level height (unit: meter) × gravity acceleration (9.8) × (measured medium density-capillary filling liquid density) (unit: g / cm3) = differential pressure range (unit: KPa ).
      The type selection must know the measurement medium, measuring range, medium temperature, pressure, capillary length, process connection flange size and pressure rating, and flange standard.

    2. Configuration


    TypeSpecification CodeIllustration
    ML3¨¨¨S---------------------------------Remote Transmission Differential Pressure & Pressure Transmitter
    Accuracy3--------------------------------±0.5%
    0--------------------------------±0.075%
    Output5--------------------------------4-20mA, HART
    Sensor1--------------------------------Capacitive Sensor
    S--------------------------------
    Connection Medium ModeY--------------------------------Remote Transmission Mounting Flange Type
    Measuring Range4--------------------------------0-6.2~37.4KPa(0-635~3810mmH2O)
    5--------------------------------0-31.1~186.8KPa(0-3175~19050mmH2O)
    6--------------------------------0-117~690KPa(0-1.2~7Kgf/cm2)
    7--------------------------------0-0.345~2.068MPa(0-3.5~21Kgf/cm2)
    8--------------------------------0-1.170~6.890MPa(0-12~70Kgf/cm2)
    Remote Transmission DeviceS1--------------------------------One remote transmission device
    Two remote transmission device
    Order according to table I,II,III,IV,V,VI
    S2--------------------------------
    Display HeaderD--------------------------------Multiple Parameters and Methods Digital LED Display Header
    N--------------------------------No Display Header
    Electrical Interface5--------------------------------M20*1.5 Waterproof Concentrator
    Additional Type-NF1----------------------------Ex-proof Security Certification: Exd II CT6
    -NS1----------------------------Intrinsic Safety Certification: Exi II CT4
    -M-------------------------------Other requirements are available
    Remarks:
    e.g.:ML3051SY-7S2D5-NF1(Basic Type Configuration)
    1199RF21A11A21-30(Refer to Table I~VI)



    3. Dimension

    Capacitive Gas Absolute DP Transmitter With Single FlangeCapacitive Gas Absolute DP Transmitter With Single Flange


    Dimension of Differential Pressure/Pressure Transmitter with Remote Device


    4. Pressure Level Transmitter
    Gauge Pressure Transmitter
    Differential Pressure Transmitter
    Capacitance Level Transmitter
    Hydrostatic Level Transmitter
    Submersible Level Transmitter


    Quality Capacitive Gas Absolute DP Transmitter With Single Flange for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)